644 research outputs found

    Subset measurement selection for globally self-optimizing control of Tennessee Eastman process

    Get PDF
    The concept of globally optimal controlled variable selection has recently been proposed to improve self-optimizing control performance of traditional local approaches. However, the associated measurement subset selection problem has not be studied. In this paper, we consider the measurement subset selection problem for globally self-optimizing control (gSOC) of Tennessee Eastman (TE) process. The TE process contains substantial measurements and had been studied for SOC with controlled variables selected from individual measurements through exhaustive search. This process has been revisited with improved performance recently through a retrofit approach of gSOC. To extend the improvement further, the measurement subset selection problem for gSOC is considered in this work and solved through a modification of an existing partially bidirectional branch and bound (PB3) algorithm originally developed for local SOC. The modified PB3 algorithm efficiently identifies the best measurement candidates among the full set which obtains the globally minimal economic loss. Dynamic simulations are conducted to demonstrate the optimality of proposed results

    Retrofit self-optimizing control of Tennessee Eastman process

    Get PDF
    This paper considers near-optimal operation of the Tennessee Eastman (TE) process by using a retrofit self-optimizing control (SOC) approach. Motivated by the factor that most chemical plants in operation have already been equipped with a workable control system for regulatory control, we propose to improve the economic performance by controlling some self-optimizing controlled variables (CVs). Different from traditional SOC methods, the proposed retrofit SOC approach improves economic optimality of operation through newly added cascaded SOC loops, where carefully selected SOC CVs are maintained at constant by adjusting set-points of the existing regulatory control loops. To demonstrate the effectiveness of the retrofit SOC proposed, we adopted measurement combinations as the CVs for the TE process, so that the economic cost is further reduced comparing to existing studies where single measurements are controlled. The optimality of the designed control architecture is validated through both steady state analysis and dynamic simulations

    Proper Scaling of the Anomalous Hall Effect

    Full text link
    Working with epitaxial films of Fe, we succeeded in independent control of different scattering processes in the anomalous Hall effect. The result appropriately accounted for the role of phonons, thereby clearly exposing the fundamental flaws of the standard plot of the anomalous Hall resistivity versus longitudinal resistivity. A new scaling has been thus established that allows an unambiguous identification of the intrinsic Berry curvature mechanism as well as the extrinsic skew scattering and side-jump mechanisms of the anomalous Hall effect.Comment: 5 pages, 4 figure

    Artificial intelligence and automation in valvular heart diseases

    Get PDF
    Artificial intelligence (AI) is gradually changing every aspect of social life, and healthcare is no exception. The clinical procedures that were supposed to, and could previously only be handled by human experts can now be carried out by machines in a more accurate and efficient way. The coming era of big data and the advent of supercomputers provides great opportunities to the development of AI technology for the enhancement of diagnosis and clinical decision-making. This review provides an introduction to AI and highlights its applications in the clinical flow of diagnosing and treating valvular heart diseases (VHDs). More specifically, this review first introduces some key concepts and subareas in AI. Secondly, it discusses the application of AI in heart sound auscultation and medical image analysis for assistance in diagnosing VHDs. Thirdly, it introduces using AI algorithms to identify risk factors and predict mortality of cardiac surgery. This review also describes the state-of-the-art autonomous surgical robots and their roles in cardiac surgery and intervention

    Evidence of the side jump mechanism in the anomalous Hall effect in paramagnets

    Full text link
    Persistent confusion has existed between the intrinsic (Berry curvature) and the side jump mechanisms of anomalous Hall effect (AHE) in ferromagnets. We provide unambiguous identification of the side jump mechanism, in addition to the skew scattering contribution in epitaxial paramagnetic Ni34_{34}Cu66_{66} thin films, in which the intrinsic contribution is by definition excluded. Furthermore, the temperature dependence of the AHE further reveals that the side jump mechanism is dominated by the elastic scattering

    Dynamics simulation research on load vehicle of deep submergence rescue vehicle (LV-DSRV)

    Get PDF
    Submarine accidents can cause loss of human life and economy, as well as environment damage. Also submarine rescue is difficult for the complexity of rescue process and the uncertainty of the sea state. Success of rescue process is determined by reliability and safety of rescue device. Therefore, research on related device design is rather important. The existing knowledge always supplies some empirical formulas and generates a design scheme by general design rules. The scheme plan obtained may not be a good one due to simplicity of mechanical calculation analysis and particularity of design requirements. To improve design safety and reliability of shipborne device on submarine rescue system, dynamics simulation model of LV-DSRV based on sea state excitation was created in this paper. Wave excitation input at sea state 5 and 8 was considered as the extreme marine working conditions. Kinetic property of LV-DSRV was calculated making use of virtual prototype technology through ADAMS software, and mechanical characteristics of key parts were also analyzed. Optimization strategy was proposed and verified by increasing the number of horizontal wheels and adding gap between horizontal wheels and the track, providing with a case study for similar marine special mechanism design

    Recipient Outcomes after ABO-Incompatible Liver Transplantation: A Systematic Review and Meta-Analysis

    Get PDF
    BACKGROUND: ABO-incompatible live transplantation (ILT) is not occasionally performed due to a relative high risk of graft failure. Knowledge of both graft and patient survival rate after ILT is essential for donor selection and therapeutic strategy. We systematically reviewed studies containing outcomes after ILT compared to that after ABO-compatible liver transplantation (CLT). METHODOLOGY/PRINCIPAL FINDINGS: We carried out a comprehensive search strategy on MEDLINE (1966-July 2010), EMBASE (1980-July 2010), Biosis Preview (1969-July 2010), Science Citation Index (1981-July 2010), Cochrane Database of Systematic Reviews (Cochrane Library, issue 7, 2010) and the National Institute of Health (July 2010). Two reviewers independently assessed the quality of each study and abstracted outcome data. Fourteen eligible studies were included which came from various medical centers all over the world. Meta-analysis results showed that no significantly statistical difference was found in pediatric graft survival rate, pediatric and adult patient survival rate between ILT and CLT group. In adult subgroup, the graft survival rate after ILT was significantly lower than that after CLT. The value of totally pooled OR was 0.64 (0.55, 0.74), 0.92 (0.62, 1.38) for graft survival rate and patient survival rate respectively. The whole complication incidence (including acute rejection and biliary complication) after ILT was higher than that after CLT, as the value of totally pooled OR was 3.02 (1.33, 6.85). Similarly, in acute rejection subgroup, the value of OR was 2.02 (1.01, 4.02). However, it was 4.08 (0.90, 18.51) in biliary complication subgroup. CONCLUSIONS/SIGNIFICANCE: In our view, pediatric ILT has not been a contraindication anymore due to a similar graft and patient survival rate between ILT and CLT group. Though adult graft survival rate is not so satisfactory, ILT is undoubtedly life-saving under exigent condition. Most studies included in our analysis are observational researches. Larger scale of researches and Randomized-Control Studies are still needed
    • …
    corecore